Scenario: Temperature Sensor Malfunction

Context

On November 18, 2025, the temperature sensor at Pelion station began reporting unrealistic values (99°C), while neighboring stations showed normal readings.

Detection Run

python anomaly_detector.py \
  --end "2025-11-18 16:00:00" \
  --window 6 \
  --temporal-method arima \
  --spatial-verify

Console Output

═══════════════════════════════════════════════
 ANOMALY DETECTION REPORT
═══════════════════════════════════════════════
End Time: 2025-11-18 16:00:00
Window: 6 hours
Method: arima
Spatial Verification: Enabled

Total Stations: 14
Anomalous Stations: 1
Normal Stations: 13

Anomaly Breakdown:
  🔴 Device Failures: 1      <-- ⚠️ ACTION REQUIRED!
  🌧️ Weather Events: 0
  ⚠️ Suspected: 0

═══════════════════════════════════════════════
 DETAILED REPORTS
═══════════════════════════════════════════════

[ STATION: pelion (Pelion Mountain) ]
  🔴 Temperature Anomaly:
      Method: arima
      Expected: 5.2°C | Actual: 99.0°C
      • 2025-11-18 16:00:00: 99.00°C -> 🔴 Device Failure
        └─ Diag: Trend Inconsistent (Corr: 0.05, 2 neighbors)

═══════════════════════════════════════════════
 NEIGHBOR COMPARISON - Station: pelion
═══════════════════════════════════════════════

Time                 | pelion  | zagora | volos
---------------------|---------|--------|-------
2025-11-18 10:00:00  | 5.2     | 8.1    | 10.2
2025-11-18 10:30:00  | 5.3     | 8.2    | 10.3
2025-11-18 11:00:00  | 5.4     | 8.3    | 10.4
2025-11-18 11:30:00  | 5.3     | 8.2    | 10.5
2025-11-18 12:00:00  | 5.2     | 8.1    | 10.6
2025-11-18 12:30:00  | 5.1     | 8.0    | 10.7
2025-11-18 13:00:00  | 5.0     | 7.9    | 10.8
2025-11-18 13:30:00  | 4.9     | 7.8    | 10.9
2025-11-18 14:00:00  | 4.8     | 7.7    | 11.0
2025-11-18 14:30:00  | 4.9     | 7.6    | 11.1
2025-11-18 15:00:00  | 5.0     | 7.7    | 11.2
2025-11-18 15:30:00  | 5.1     | 7.8    | 11.3
2025-11-18 16:00:00  | 99.0 🔴 | 7.9    | 11.4

Observation: pelion suddenly jumps to 99°C while neighbors remain stable
→ Classification: Device Failure (Sensor Error)

RECOMMENDATION: Inspect Pelion station temperature sensor

Analysis

Why Was This Classified as Device Failure?

  1. Isolated Anomaly: Only 1 station affected (out of 14)
  2. Low Spatial Correlation: 0.05 (<< 0.3 threshold)
  3. Unrealistic Value: 99°C is physically impossible for this location (mountain, altitude 1200m)
  4. Neighbors Normal: Nearby stations show stable, expected temperatures

Spatial Correlation Details

Station Pair       | Correlation | Distance | Neighbor Trend
-------------------|-------------|----------|----------------
pelion ↔ zagora    | 0.03        | 32.1 km  | Stable ~8°C
pelion ↔ volos     | 0.08        | 35.4 km  | Stable ~11°C

Interpretation: Pelion's behavior is completely uncorrelated with neighbors → Isolated issue

Time Series Visualization

Temperature Comparison

Temp (°C)
   100 ┤                          ● ← pelion (ANOMALY)
    90 ┤
    80 ┤
    70 ┤
    60 ┤
    50 ┤
    40 ┤
    30 ┤
    20 ┤
    11 ┤                      ─────● volos (NORMAL)
     8 ┤                  ─────●     zagora (NORMAL)
     5 ┤──────────────●
       └─────────────────────────────
       10:00              16:00

Pattern: - Pelion: Sudden jump (physically impossible) - Neighbors: Smooth, gradual changes (normal weather)

Failure Mode Analysis

Common Sensor Failure Patterns

Pattern Likely Cause Example Value
Fixed value (99.0) Sensor disconnected 99.0, 999.9
Negative spikes Electrical interference -127, -999
Constant zero Power loss 0.0
Erratic jumps Loose connection 5 → 99 → 3 → 105

This case: Fixed at 99.0 → Sensor disconnected or failed

Diagnostic Steps for Technicians

  1. Check physical connection: Sensor cable may be disconnected
  2. Inspect sensor housing: Water ingress? Damage?
  3. Test voltage: Proper power supply to sensor?
  4. Check datalogger: Error codes in station logs?
  5. Replace sensor: If steps 1-4 show no issue

What Would Happen Without Spatial Verification?

# Without --spatial-verify
python anomaly_detector.py \
  --end "2025-11-18 16:00:00" \
  --temporal-method arima

Result:

Anomaly Breakdown:
  🔴 Device Failures: 1      <-- Still flagged, but no confirmation
  🌧️ Weather Events: 0
  ⚠️ Suspected: 0

Problem: - Without spatial verification, we can't be confident - Could it be an extreme microclimate event? - Could it be a wildfire nearby?

With spatial verification: - ✅ Confirmed as device failure (neighbors normal) - ✅ High confidence → immediate technician dispatch - ✅ No false investigation of "extreme weather"

Real-World Impact

Before Dual-Verification

Operator receives alert → Checks weather reports → Sees clear skies → 
Still uncertain if it's sensor or real → Waits for more data → 
Sensor remains broken for hours/days

After Dual-Verification

System reports "Device Failure" → Operator immediately dispatches technician → 
Sensor replaced within 4 hours → Data integrity restored

Time saved: ~24 hours
False investigations: 0


Alert Message

Email Alert (Example)

Subject: 🔴 URGENT - Device Failure Detected at Pelion Station

Station: pelion (Pelion Mountain)
Variable: Temperature (temp_out)
Timestamp: 2025-11-18 16:00:00

Anomaly Details:
  - Expected: 5.2°C
  - Actual: 99.0°C
  - Deviation: +93.8°C

Spatial Verification:
  - Correlation with neighbors: 0.05 (very low)
  - Neighbors checked: zagora, volos
  - Neighbor status: All normal

Classification: DEVICE FAILURE (High Confidence)

Action Required:
  ☐ Dispatch technician to Pelion station
  ☐ Check temperature sensor connection
  ☐ Inspect for physical damage
  ☐ Replace sensor if necessary

Dashboard: https://dashboard.example.com/stations/pelion
Report: /var/log/weather/reports/report_20251118_160000.json

Comparison: Weather Event vs Device Failure

Characteristic Weather Event Device Failure
Affected Stations Multiple (≥3) Single (1)
Spatial Correlation High (>0.6) Low (<0.3)
Value Plausibility Realistic Often unrealistic
Neighbor Behavior Similar pattern Normal/different
Temporal Pattern Gradual change Sudden jump
Action Required None Dispatch technician

Example Values

Weather Event:
  Station A: 15°C → 10°C (gradual drop)
  Station B: 16°C → 11°C (gradual drop)
  Station C: 14°C → 9°C  (gradual drop)
  Correlation: 0.89 ✅

Device Failure:
  Station A: 5°C → 99°C  (sudden jump)
  Station B: 8°C → 8°C   (stable)
  Station C: 11°C → 11°C (stable)
  Correlation: 0.05 ❌

Post-Incident Analysis

Technician Report (Example)

Date: 2025-11-18
Station: Pelion Mountain
Issue: Temperature sensor failure

Findings:
  - Sensor cable disconnected from datalogger
  - Cable connection corroded due to moisture
  - Sensor itself functional when tested separately

Actions Taken:
  - Cleaned and reconnected cable
  - Applied dielectric grease to prevent corrosion
  - Verified readings: Now reporting 5.3°C (expected for altitude)
  - Added cable strain relief

Preventive Measures:
  - Schedule quarterly inspections of cable connections
  - Consider upgrading to sealed waterproof connectors

Validation After Repair

# Run detection again after repair
python anomaly_detector.py \
  --end "2025-11-18 18:00:00" \
  --spatial-verify

Result:

Total Stations: 14
Anomalous Stations: 0
Normal Stations: 14

✅ All stations operating normally

Key Takeaways

  1. Low correlation (<0.3) = Device failure - Strong indicator of isolated issue
  2. Unrealistic values - 99°C at mountain station is physically impossible
  3. Spatial verification provides confidence - Enables immediate action without doubt
  4. Typical failure mode - Fixed value (99.0) suggests disconnected sensor
  5. Quick resolution - Clear classification → fast technician dispatch → rapid fix